Summary
Microvascular clamps of various designs provide a bloodless field for a safe anastomosis
but can cause intimal lesions, occupy space in confined sites and have a risk of backwalling
due to vessel flattening. They are often insufficient in their haemostatic effect
in plaque-filled atherosclerotic vessels. A new, CE-certified thermosensitive gel
(LeGoo™) clinically proven in cardiovascular surgery allows a clampless microanastomosis
technique.
We operated on a series of five consecutive patients aged 24–71 years with six flaps
for lower-extremity reconstruction using a clampless anastomosis technique with LeGoo™.
We transplanted one fabricated chimaeric fibula plus gracilis, three gracilis muscle
and one anterolateral thigh (ALT) flap. Pre- and postoperative protocols were similar
to a ‘standard’ procedure with micro-clamps.
All flaps survived completely except for a small area on fibula skin island, which
was unrelated to gel use. The gel-assisted technique has a quick learning curve, according
to this case series. The veins should be sutured first to prevent stasis in the flap.
The gel provides circular stenting and gentle distension of the vessels for a safe
and blood-free anastomotic site. It is completely dissolved after completion of the
anastomosis with cold saline irrigation. Repolymerisation in the periphery will not
occur, making it safe for microvascular flap surgery.
From the experiences from this series and other specialities, the use of the thermosensitive
gel LeGoo™ permits a safe clampless microanastomosis technique minimising mechanical
vessel manipulation and compression. This makes it an attractive alternative to micro-clamps,
especially for atherosclerotic arteries and confined anastomosis sites.
Keywords
To read this article in full you will need to make a payment
Purchase one-time access:
Academic & Personal: 24 hour online accessCorporate R&D Professionals: 24 hour online accessOne-time access price info
- For academic or personal research use, select 'Academic and Personal'
- For corporate R&D use, select 'Corporate R&D Professionals'
Subscribe:
Subscribe to Journal of Plastic, Reconstructive & Aesthetic SurgeryAlready a print subscriber? Claim online access
Already an online subscriber? Sign in
Register: Create an account
Institutional Access: Sign in to ScienceDirect
References
- New instruments for microvascular surgery.Br J Surg. 1972; 59: 181-184
- Temporary microvascular clips.Neurosurgery. 1979; 5: 456-463
- Intimal injury from arterial clamps.Am J Surg. 1976; 132: 183-188
- Differential endothelial injury caused by vascular clamps and vessel loops. I. Normal vessels.Am Surg. 1985; 51: 392-400
- Structural recovery of small arteries following clamp injury: a light and electron microscopic investigation in the rat.Microsurgery. 1996; 17: 674-680
- Differential endothelial injury caused by vascular clamps and vessel loops. II. Atherosclerotic vessels.Am Surg. 1985; 51: 401-406
- Endovascular temporary vessel occlusion with a reverse-thermosensitive polymer for bloodless minimally invasive renal surgery.J Vasc Interv Radiol. 2010; 21: 711-718
- Thermosensitive polymer use for shunt sealing in off-pump coronary artery bypass.Innovations. 2010; 5: 122-124
- Safety and efficacy of a novel gel for vascular occlusion in off-pump surgery.Ann Thorac Surg. 2005; 80: 2333-2337
- Clinical experience with a novel thermosensitive temporary coronary artery occluder (LeGoo).Ann Thorac Surg. 2010; 89: 1912-1917
- Facilitated anastomosis using a reverse thermo-sensitive polymer for temporary coronary occlusion in off-pump minimally invasive direct coronary artery bypass surgery.Interact Cardiovasc Thorac Surg. 2010; 11: 532-536
- Hemostatic control of coronary arteries with poloxamer 407 reverse-thermal polymer during off-pump coronary artery bypass surgery in a pig model.Innovations. 2007; 2: 36-39
- Evaluation of a novel reverse thermosensitive polymer for use in microvascular surgery.J Reconstr Microsurg. 2009; 25: 69-76
- Temporary vascular occlusion with poloxamer 407.Biomaterials. 2004; 25: 3983-3989
- Effects of purified poloxamer 407 gel on vascular occlusion and the coronary endothelium.Eur J Cardiothorac Surg. 2006; 29: 736-741
- Temporary coronary artery occlusion during off-pump coronary artery bypass grafting with the new poloxamer P407 does not cause endothelial dysfunction in epicardial coronary arteries.J Thorac Cardiovasc Surg. 2006; 132: 1144-1149
- Temporary segmental renal artery occlusion using reverse phase polymer for bloodless robotic partial nephrectomy.J Urol. 2009; 182: 1582-1587
Article info
Publication history
Published online: August 08, 2011
Accepted:
July 13,
2011
Received:
July 7,
2011
Identification
Copyright
© 2011 British Association of Plastic, Reconstructive and Aesthetic Surgeons. Published by Elsevier Inc. All rights reserved.